Description
Description
EMX IRB-MON2 Through-Beam Photoeyes
Replacing the original IRB-MON, the IRB-MON2 is a monitored, weather-proof, thru beam infrared photoeye solution providing entrapment protection for doors, gates and barriers. The IRB-MON2 Safety Photo Beam is UL325 compliant and housed in an IP65 rated enclosure suitable for indoor and outdoor use.
This universal UL325 thru beam photoeye can be used with a wide variety of monitored operators. Additionally, the IRB-MON2 photoeye is compatible with most non-monitored legacy products. Its robust construction minimizes fogging and false triggering to provide easy alignment.
The IRB-MON2 thru beam infrared photoeye is an external entrapment protection device type B1, non-contact sensor for use with automatic gates and doors. The photoeye provides a signal to the gate or door operator that the beam is, or is not obstructed. It operates up to 115 feet over a wide range of input voltages (6-35 VDC and 12-24 VAC). The receiver green alignment indicator provides status information, making set-up and alignment easy. The IRB-MON2 provides compatibility with most operators that accommodate monitored external entrapment devices per UL325.
Features
- 115 ft. operating range
- Enhanced version of the original IRB-MON
- Advanced features in a compact design
- Integrated sensor hood for element protection
- Removable terminal block for easy wiring
- IRB-MON2 can be used in non-monitored applications using standard NC/NO contacts
- Various UL325 Monitoring Methods for adaptability
- 0.83″ (21.3 mm) Conduit Hole – large enough for 1/2 Inch NPT
- 115 ft. Operating Range
- Detachable Screw Terminals
- IRB-MON2 can be used in non-monitored applications using standard NC/NO contacts
Specifications
- Operating Range: 5 to 115 ft (35 m)
- Power: 6-35 VDC, 12-24 VAC
- Current (NC and 10K Monitoring Methods): 35 mA DC (when aligned and relay activated)
- Current (Pulse Monitoring Methods): 15 mA
- Connections: “Removable” screw terminal for easy wiring
- Supported Monitoring Methods: 10K, 2-wire pulse, Normally Closed (power cycle)
- Relay Output Configuration: Form C contacts (NO, COM, NC)
- Response Time: <300 ms (for use in NC or 10K monitoring)
- Operating Temperature: -40° to 170°F (-40° to 77°C)
- Dimensions: (L x W x H) 3.6” (91 mm) x 2.9” (74 mm) x 2.9” (74 mm)
- Conduit Hole Size (bottom of the housing): 0.83″ (21.3 mm) – large enough for 1/2 Inch NPT
Featuring 4 monitoring interfaces:
- Normally closed
- Two-wire pulsed (2 frequencies)
- Two-wire pulsed (3 frequencies)
- 10k resistive termination
Included With This Kit
- Transmitter
- Receiver,
- Integrated protective hoods
- Removable lens sunshield
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.