{"product_id":"maximum-controls-mxdsp-swing-actuator-control-board","title":"Maximum Controls MXDSP Swing Actuator Control Board","description":"\u003ch2\u003eGenuine OEM Control Board for Maximum Controls Swing Actuator Gate Operators\u003c\/h2\u003e\n\u003cp\u003eThe MXDSP is the genuine OEM Maximum Controls DSP Arm Controller, the main control board for Maximum Controls swing actuator gate operators including the Max Arm, Max Super Arm 1300, Max Super Arm 2300, and Max Ultra Arm. Mounted inside the operator's control box, the MXDSP drives the actuator motor or motors, manages all gate-cycle logic, interfaces with safety sensors, accessory devices, and access control inputs, and provides the diagnostic and programming interface for the installation. The MXDSP is the correct factory-sourced replacement when the existing control board fails due to lightning damage, water intrusion, power surge, or extended service life.\u003c\/p\u003e\n\u003cp\u003eBeyond standard motor control, the MXDSP carries 16-position ERD (Electronic Reversing Device) sensitivity adjustment for both opening and closing directions with independent motor overload monitoring on Motor 1 and Motor 2, monitored UL 325 2018 entrapment protection inputs for both Normally Closed and 10K resistor-terminated sensors with separate channels for Opening, Photo Close, and Open-Close sensor placements, an integrated three-slot loop detector rack for Exit, Center, and Safety loops, and built-in maglock control with adjustable disengagement timing. The on-board LCD display and programming buttons walk the installer through date and time setup, mode configuration, and feature toggles in plain language, removing guesswork from the commissioning process. A USB OBD and Black Box port logs the last 8,000 events to any standard USB flash drive for download to a computer or smartphone, giving installers full event history for field diagnostics.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal across the Maximum Controls swing actuator gate operator line, supporting the Max Arm, Max Super Arm 1300, Max Super Arm 2300, and Max Ultra Arm through DIP-switch configuration of actuator type and gate length category\u003c\/li\u003e\n\u003cli\u003eSingle or dual operator support selectable via the on-board operator switch, controlling bi-parting gate pairs from a single board\u003c\/li\u003e\n\u003cli\u003eThree battery backup power-fail modes (Leave Open, Leave Closed, Open 1 Time) configurable to the site's access and security requirements during AC outages\u003c\/li\u003e\n\u003cli\u003eSolar Mode selection reduces standby power draw for solar-powered installations and extends battery runtime\u003c\/li\u003e\n\u003cli\u003eMonitored UL 325 2018 entrapment protection inputs accept both Normally Closed and 10K-terminated sensors across separate channels for Opening, Photo Close, and Open-Close placements\u003c\/li\u003e\n\u003cli\u003eBuilt-in event logging stores the last 8,000 events to the integrated USB OBD and Black Box port for download to any computer or smartphone, simplifying field diagnostics and warranty documentation\u003c\/li\u003e\n\u003cli\u003e16-position ERD sensitivity adjustment per direction with independent motor overload indicators for Motor 1 and Motor 2\u003c\/li\u003e\n\u003cli\u003eThree internal loop detector slots (Exit, Center, Safety) with external loop detector input also supported via the seven-pin terminal\u003c\/li\u003e\n\u003cli\u003eLCD display with on-board PROGRAM, navigation, motion control (Open\/Stop\/Close), and Jog buttons for full commissioning and field service without external tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e MXDSP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Maximum Controls\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DSP Arm Controller swing gate operator control board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Maximum Controls swing actuator gate operators, including Max Arm, Max Super Arm 1300, Max Super Arm 2300, and Max Ultra Arm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperator Configuration:\u003c\/strong\u003e Single or dual operator (selectable via on-board switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e 115VAC or 230VAC selectable via the Maximum Controls Toroid Box, 7A fuse, single-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Backup Support:\u003c\/strong\u003e Two 12VDC 7Ah batteries (not included with control board)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessory Power Outputs:\u003c\/strong\u003e 24VDC and 12VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntrapment Protection Inputs:\u003c\/strong\u003e UL Sensor N.C. channels (Open Only NC, Photo CLS NC, Open\/CLS NC) and UL Sensor 10K channels (Open Only 10K, Photo CLS 10K, Open\/CLS 10K), all monitored\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Detector Capacity:\u003c\/strong\u003e Three internal slots (Exit, Center, Safety) plus external loop detector input via seven-pin terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Logging:\u003c\/strong\u003e USB OBD and Black Box port, stores last 8,000 events for download to any USB-capable device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming Interface:\u003c\/strong\u003e Integrated LCD display with PROGRAM, navigation, motion control, and Jog buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eERD Sensitivity:\u003c\/strong\u003e 16 positions per direction (Opening and Closing), independent motor overload indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaglock Control:\u003c\/strong\u003e Built-in maglock relay with 1.5-second or 2.5-second disengagement delay options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess Control Inputs:\u003c\/strong\u003e Radio, Fire Department, MAX Open, Strike, Keypad\/Card, three-button station, Tamper, Gate Disable, External Alarm Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Outputs:\u003c\/strong\u003e Gate Open and Gate Closed dry contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar Mode:\u003c\/strong\u003e Selectable via on-board switch for solar-powered installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Compliance:\u003c\/strong\u003e UL 325 2018 entrapment protection compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New, genuine OEM part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConclusion\u003c\/h3\u003e\n\u003cp\u003eThe MXDSP is the correct factory replacement for the control board in any Maximum Controls swing actuator gate operator. After installation, configure the Mode A DIP switches to match the installed actuator type and gate length category per the operator manual to ensure proper ramp-down behavior and force calibration. When replacing the control board, inspect the actuator wiring harness, limit sensor cables, entrapment protection devices, and accessory power transformers for damage or wear at the same time, as electrical faults in those components are common causes of control board failure in the first place.\u003c\/p\u003e\n\u003cdiv\u003e\n  \u003cp\u003e\n\u003ca class=\"elite-button\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/MXDSP_manual.pdf\" target=\"_blank\"\u003eInstallation \/ User Manual\u003c\/a\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Maximum Controls","offers":[{"title":"Default Title","offer_id":49155692626228,"sku":"MXDSP","price":887.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/MXDSP.jpg?v=1781122458","url":"https:\/\/elitegates.net\/products\/maximum-controls-mxdsp-swing-actuator-control-board","provider":"Elite Gates","version":"1.0","type":"link"}