{"product_id":"liftmaster-la500slrharn-solar-harness-for-la500","title":"LiftMaster LA500SLRHARN Solar Harness for LA500","description":"\u003ch2\u003e33Ah Battery Wiring Kit for LA500 Solar Applications\u003c\/h2\u003e\n\u003cp\u003eThe LiftMaster LA500SLRHARN Solar Harness Kit is a replacement and installation harness for LiftMaster LA500 gate operator solar applications using 33Ah batteries. This harness is required for 33Ah solar configurations only and is used to connect the larger battery setup and solar panel wiring to the LA500 control system.\u003c\/p\u003e\n\u003cp\u003eThe kit includes the solar harness and battery jumper wire needed for the 33Ah battery layout. The harness has long red and black wires for the 33Ah battery connections and shorter red and black wires for the solar panel connections. This allows the LA500 solar system to be wired according to LiftMaster’s specified battery and solar panel configuration.\u003c\/p\u003e\n\u003cp\u003eThe LA500SLRHARN is intended for solar-powered LA500 installations where higher-capacity 33Ah batteries are being used instead of the standard battery configuration. It is commonly used during solar conversions, battery box updates, replacement harness repairs, or service work on LA500 gate systems configured for 33Ah battery backup.\u003c\/p\u003e\n\u003cp\u003eSolar panels, batteries, gate operator, and control box are not included. Installation should follow the LA500 manual and LiftMaster solar harness wiring diagram, and all AC, solar, and battery power must be disconnected before service.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLiftMaster solar harness kit for LA500 gate operators\u003c\/li\u003e\n\u003cli\u003eModel LA500SLRHARN\u003c\/li\u003e\n\u003cli\u003eRequired for 33Ah LA500 solar applications only\u003c\/li\u003e\n\u003cli\u003eSupports LA500 solar configurations using 33Ah batteries\u003c\/li\u003e\n\u003cli\u003eIncludes battery jumper wire\u003c\/li\u003e\n\u003cli\u003eIncludes solar harness with battery and solar panel leads\u003c\/li\u003e\n\u003cli\u003eLong red and black wires connect to the 33Ah battery setup\u003c\/li\u003e\n\u003cli\u003eShort red and black wires connect to the solar panel wiring\u003c\/li\u003e\n\u003cli\u003eUsed for solar conversions, service repairs, and 33Ah battery configuration updates\u003c\/li\u003e\n\u003cli\u003eSupports LiftMaster’s 20W, 40W, and 60W solar panel wiring layouts when configured according to the manual\u003c\/li\u003e\n\u003cli\u003eDesigned for use with the LA500 large metal control box solar wiring layout\u003c\/li\u003e\n\u003cli\u003eBatteries and solar panels sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e LiftMaster\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e LA500SLRHARN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Solar harness kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Operator:\u003c\/strong\u003e LiftMaster LA500 gate operator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e 33Ah solar battery applications only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Configuration:\u003c\/strong\u003e For LA500 solar systems using 33Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarness Connections:\u003c\/strong\u003e Long red and black wires for 33Ah battery connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar Panel Connections:\u003c\/strong\u003e Short red and black wires for solar panel connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Components:\u003c\/strong\u003e Solar harness and battery jumper wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar Panel Reference:\u003c\/strong\u003e LiftMaster diagram illustrates 10W 12V panels arranged for 20W, 40W, or 60W solar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Box Reference:\u003c\/strong\u003e LA500 large metal control box solar application wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot Included:\u003c\/strong\u003e LA500 gate operator, control box, batteries, solar panels, mounting hardware, or additional wiring not listed by LiftMaster\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Safety Requirement:\u003c\/strong\u003e Disconnect AC, solar, and battery power before servicing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirement:\u003c\/strong\u003e Electrical connections must be made by a qualified individual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Note:\u003c\/strong\u003e Refer to the LA500 manual and LiftMaster solar harness diagram for complete wiring instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConclusion\u003c\/h3\u003e\n\u003cp\u003eThe LiftMaster LA500SLRHARN Solar Harness Kit provides the required wiring harness and jumper wire for LA500 gate operator systems configured with 33Ah batteries in solar applications. It is a specific harness for 33Ah LA500 solar setups and should be installed according to LiftMaster’s wiring diagram with all power sources disconnected before service.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/LA500SLRHARN_manual.pdf\" class=\"elite-button\" target=\"_blank\"\u003eDownload Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"LiftMaster","offers":[{"title":"Default Title","offer_id":49193054503220,"sku":"LA500SLRHARN","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/LA500SLRHARN.jpg?v=1784225624","url":"https:\/\/elitegates.net\/products\/liftmaster-la500slrharn-solar-harness-for-la500","provider":"Elite Gates","version":"1.0","type":"link"}