{"product_id":"liftmaster-cap4expnd-smart-access-expansion-board","title":"LiftMaster CAP4EXPND Smart Access Expansion Board","description":"\u003ch2\u003eExpansion Board for LiftMaster Smart Access Control Systems\u003c\/h2\u003e\n\u003cp\u003eThe LiftMaster CAP4EXPND Smart Access Expansion Board is an I\/O expansion module for LiftMaster myQ Community access control systems. It is used with the LiftMaster Smart Access Controller Panel CAPXAP and its control board, CAPXAP-CNTL, to add additional access point control inside the panel. It also serves as the service replacement expansion board for the LiftMaster CAP4AP Smart Access Controller.\u003c\/p\u003e\n\u003cp\u003eEach CAP4EXPND board provides four relays, four supervised inputs, and two Wiegand inputs. This allows the connected controller system to manage additional gates, doors, readers, request-to-exit devices, door or gate status inputs, Knox Box inputs, supervised gate operator inputs, and fire alarm interface functions depending on the system configuration.\u003c\/p\u003e\n\u003cp\u003eFor gate and door access control, the relays can be used for gate operators, door strikes, maglocks, alarm shunts, lighting control circuits, and other low-voltage control functions. The supervised inputs can be configured for REX, free-exit loop detectors, door sensors, proximity sensors, Knox Box input, fire alarm interface, or supervised gate operator status. Wiegand inputs support compatible proximity readers, keypads, and RFID devices when configured through the LiftMaster access control platform.\u003c\/p\u003e\n\u003cp\u003eThe CAP4EXPND is intended for professional access control installations and service work. It does not provide network connectivity, cloud management, PoE, Wi-Fi, or standalone access control by itself. Those functions are handled by the compatible LiftMaster control board and myQ Community system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLiftMaster Smart Access Expansion Board\u003c\/li\u003e\n\u003cli\u003eModel CAP4EXPND\u003c\/li\u003e\n\u003cli\u003eExpansion module for LiftMaster CAPXAP Smart Access Controller Panel\u003c\/li\u003e\n\u003cli\u003eService replacement expansion board for LiftMaster CAP4AP\u003c\/li\u003e\n\u003cli\u003eAdds control for up to 4 additional gates, doors, or access points when used in a compatible system\u003c\/li\u003e\n\u003cli\u003eProvides 4 relay outputs\u003c\/li\u003e\n\u003cli\u003eProvides 4 supervised inputs\u003c\/li\u003e\n\u003cli\u003eProvides 2 Wiegand inputs\u003c\/li\u003e\n\u003cli\u003eSupports gate operators, door strikes, maglocks, lights, and alarm shunt control circuits\u003c\/li\u003e\n\u003cli\u003eSupports REX, free-exit loop detectors, proximity sensors, door sensors, Knox Box inputs, supervised gate operator inputs, and fire alarm interface functions\u003c\/li\u003e\n\u003cli\u003eWiegand inputs support compatible readers, keypads, and RFID devices\u003c\/li\u003e\n\u003cli\u003eSupports Wiegand output integration where supported by the connected controller configuration\u003c\/li\u003e\n\u003cli\u003eDesigned for myQ Community access control systems\u003c\/li\u003e\n\u003cli\u003eNot a standalone controller\u003c\/li\u003e\n\u003cli\u003eIntended for professional installation and service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e LiftMaster \/ The Chamberlain Group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e CAP4EXPND\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Smart access expansion board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Use:\u003c\/strong\u003e I\/O expansion board for LiftMaster Smart Access control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPXAP Use:\u003c\/strong\u003e Expansion module for LiftMaster CAPXAP and CAPXAP-CNTL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAP4AP Use:\u003c\/strong\u003e Service replacement expansion board for LiftMaster CAP4AP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Gates \/ Doors Controlled:\u003c\/strong\u003e 4 per board, when used in a compatible system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Use:\u003c\/strong\u003e Gate operator, door strike, maglock, alarm shunt, light, or control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervised Inputs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervised Input Functions:\u003c\/strong\u003e REX, Knox Box, door status, supervised gate operator status, and fire alarm interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiegand Inputs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiegand Input Use:\u003c\/strong\u003e Compatible proximity readers, keypads, and RFID devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiegand Output Data Reference:\u003c\/strong\u003e 26-bit credentials or passthrough where supported by system configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -4°F to 122°F, -20°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Platform:\u003c\/strong\u003e myQ Community, through compatible LiftMaster controller hardware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Controller:\u003c\/strong\u003e Compatible LiftMaster CAPXAP or CAP4AP system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandalone Operation:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e Provided by the compatible controller, not by this expansion board alone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \/ Communication Interface:\u003c\/strong\u003e Connects to the compatible LiftMaster control board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Component:\u003c\/strong\u003e CAP4EXPND expansion board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot Included:\u003c\/strong\u003e CAPXAP panel, CAP4AP controller, CAPXAP-CNTL control board, readers, keypads, credentials, locks, gate operators, power supplies for locks, wiring, or mounting hardware unless specifically stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirement:\u003c\/strong\u003e Must be installed and serviced by a professional access control installer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 years for parts and hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConclusion\u003c\/h3\u003e\n\u003cp\u003eThe LiftMaster CAP4EXPND adds relay, supervised input, and Wiegand reader capacity to compatible LiftMaster Smart Access control systems. It is used as an expansion board for CAPXAP installations and as the service replacement expansion board for CAP4AP units. It should be selected when the system design or service repair calls for the CAP4EXPND board specifically.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/CAP4AP_brochure.pdf\" class=\"elite-button\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/CAP4EXPND_specs.pdf\" class=\"elite-button\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\n\u003c\/div\u003e","brand":"LiftMaster","offers":[{"title":"Default Title","offer_id":49193077571892,"sku":"CAP4EXPND","price":577.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0141\/9617\/8998\/files\/CAP4EXPND.jpg?v=1784231530","url":"https:\/\/elitegates.net\/products\/liftmaster-cap4expnd-smart-access-expansion-board","provider":"Elite Gates","version":"1.0","type":"link"}